NIOSH Guide to the Selection and Use of Particulate Respirators Certified Under 42 CFR 84/Appendix A
PART 11 AND PART 84 LABELS FOR VARIOUS FILTERS
PART 11 LABEL FOR HEPA FILTERPERMISSIBLE
PERMISSIBLE PARTICULATE FILTER RESPIRATOR FOR DUSTS, FUMES, AND MISTS, INCLUDING MINE SAFETY AND HEALTH ADMINISTRATION
APPROVAL NO. TC-21C-XXX ISSUED TO ABC Company LIMITATIONS Approved for respiratory protection against dusts, fumes and mists having a fine-weighted average of less than 0.05 milligram per cubic meter, including asbestos-containing dusts and mists, and radionuclides. Not for use in atmospheres containing toxic gases or vapors. Not for use in atmospheres immediately dangerous to life or health. Not for use in atmospheres containing less than 19.5% oxygen. CAUTION In making renewals or repair, parts identical with those furnished by the manufacturer under the pertinent approval shall be maintained. Follow the manufacturer's instructions for changing filters. |
MSHA/NIOSH Approval TC-21C-XXX Issued to ABC Co. February 31, 1990 The approved assembly consists of the following parts: 000-000 |
PART 84 LABEL FOR N100 AND P95 FILTER
DEF MANUFACTURING COMPANY
ANYWHERE, USA
1-800-555-1234
THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:
RESPIRATOR COMPONENTS | |||||
TC- | PROTECTION1 | FACEPIECE | FILTER | CAUTIONS AND LIMITATIONS1 | |
HALO 1000 | NO100 | PO95 | |||
84A-00X | N100 | X | X | ABCJLMNO | |
84A-00Y | P95 | X | X | ABCJLMNO |
1. PROTECTION
|
2. CAUTIONS AND LIMITATIONS
A—Not for use in atmospheres containing less than 19.5% oxygen.
B—Not for use in atmospheres immediately dangerous to life or health.
C—Do not exceed maximum use concentrations established by regulatory standards.
J—Failure to use and maintain this product properly could result in injury or death.
L—Follow the manufacturer's instructions for changing cartridges and/or filters.
M—All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N―Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration specified by the manufacturer
O—Refer to user instructions and/or maintenance manuals for information about use and maintenance of these respirators.
PART 84 LABEL FOR P100 FILTER
DEF MANUFACTURING COMPANY
ANYWHERE, USA
1-800-555-1234
THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS: | |||||
TC- | PROTECTION1 | RESPIRATOR | CAUTIONS AND LIMITATIONS1 | ||
84A-00X | P100 | HALO 2000 | ABCJMNO |
1. PROTECTION
P100-Particulate Filter (99.97% filter efficiency level) is effective against all particulate aerosols. |
2. CAUTIONS AND LIMITATIONS
A—Not for use in atmospheres containing less than 19.5% oxygen.
B—Not for use in atmospheres immediately dangerous to life or health.
C—Do not exceed maximum use concentrations established by regulatory standards.
J—Failure to use and maintain this product properly could result in injury or death.
M—All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N―Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration specified by the manufacturer
O—Refer to user instructions and/or maintenance manuals for information about use and maintenance of these respirators.