This page has been validated.
COLLECTED PHYSICAL PAPERS
35

ments. It sometimes becomes necessary to have greater intensity without the attendant trouble inseparable from too long waves. I have made a new radiator, where the oscillatory discharge takes place between two small circular plates 12 mm. in diameter and an interposed ball of platinum 9.7 mm. in diameter. The sparking takes place at right angles to the circular plates. The intensity of radiation is by this expedient very greatly increased.

In my previous experiments for determination of the index of refraction, I used tubes to surround the radiator. This I was obliged to do to protect the receiver as much as possible from external disturbances. But this procedure may be open to the objection that the sides of the tube may send reflected waves. It is preferable to have a divergent beam from a single source for a well-defined image after refraction. By the successful removal of the disturbing causes it is now possible to allow the radiator to be placed in open space, a plate with a rectangular aperture allowing the radiation to fall on the refracting cylinder along a given direction. The size of the plate is 26 × 15 cm., and the aperture is 7 × 6 cm. (see fig. 8). The radiator and the receiver are placed on opposite sides of the plate. Absence of disturbance due to lateral waves was tested by closing the aperture and observing whether the waves still affected the receiver by going round the plate. The plate was found to act as an effective screen.

I have hitherto preferred the null method in my experiments, as it possesses many advantages. The sensitiveness of the receiver can be pushed to the utmost extent, and observations taken when no effect is produced on the receiver. This method of total reflection also