ETHYL CHLORIDE: METHOD 2519, Issue 2, dated 15 August 1994 - Page 4 of 4 breakthrough capacity of 24 mg under these conditions. REFERENCES: [1] Backup Data Report, S105, available as "Ten NIOSH Analytical Methods, Set 4," Order No. PB 281-038 from NTIS, Springfield, VA 22161. [2] NIOSH Manual of Analytical Methods, 2nd ed., Vol. 4, S105, U.S. Department of Health, Education, and Welfare, Publ. (NIOSH) 78-175 (1978). [3] NIOSH/OSHA Occupational Health Guidelines for Chemical Hazards, U.S. Department of Health and Human Services, Publ. (NIOSH) 81-123 (1981), available as GPO Stock #017-033-00337-8 from Superintendent of Documents, Washington, DC 20402. [4] NIOSH Research Report - Development and Validation of Methods for Sampling and Analysis of Workplace Toxic Substances, U.S. Department of Health and Human Services, Publ. (NIOSH) 80-133 (1980).

METHOD REVISED BY: Y.T. Gagnon, NIOSH/DPSE; S105 originally validated under NIOSH Contract 210-76-0123.