SUPER ABSORBENT POLYMERS: METHOD 5035, Issue 1, dated 15 August 1994 - Page 6 of 6
Table 1 CAS Numbers, Detection Limits, and Analytical Ranges for Super Absorbent Polymers CAS Number
Detection Limit* (µg/sample)
Analytical Range (µg/sample)
Sanwet IM-3500
60323-79-7
4
15 to 1000
Water Lock A-100
65930-07-6
14
45 to 1000
Water Lock B-204
72162-30-2
13
42 to 1000
Water Lock G-400
61788-39-4
8
28 to 1000
Super Absorbent Polymer
- The detection limit is defined as three times the standard deviation of blanks. The standard
deviation of six blanks was 1.04 µg of copper per sample. The average blank value was 2.95 µg of copper. Detection limits in Table 1 are quantities of anhydrous super absorbent polymer per sample.
NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94