LEVEL CROSSINGS

The number and colour of the bells may be varied


'Table 21-1
Lowest hot weather height of contact wires Height of gauge (diagram 781) and height to be shown on supplementary plate (diagrams 780A, 780.1A and 780.2A) for different overhead line voltages Signs to be
used
25000 volts Less than 25000 volts
Imperial Metric Imperial Metric Imperial Metric
18-9" 5.71 m 16'-9" 5.1 m 17'-3" 5.2 m Diagram 779
with 780A or
780.1A
18-6" 5.64m 16'-6" 5.0m 17'-0" 5.1 m
18'-3" 5.56m 16'-9" 5.1 m
18'-0" 5.49m 16'-6" 5.0m
18'-3" 5.56m 16'-6" 5.0m - - Load gauge (diagram 781) and diagram 779 with 780.2A
18'-0" 5.49m 16'-3" 4.9m - -
17'-9" 5.41 m 16'-0" 4.8m 16'-6" 5.0m
17'-6" 5.33m 15'-9" 4.8m 16'-3" 4.9m
17'-3" 5.26m 15'-6" 4.7m 16'-0" 4.8m
17'-0" 5.18m 15'-3" 4.6m 15'-9" 4.8m
16'-9" 5.10m 15'-0" 4.5m 15'-6" 4.7m
16'-6" 5.03m 14'-9" 4.5m 15'-3" 4.6m

67