Page:United States Statutes at Large Volume 50 Part 2.djvu/354

This page needs to be proofread.

TREATIES (d.) Means whereby froth may be rapidly discharged and distrib- uted over the whole of the lower part of the boiler room or of any one boiler room, if there are more than one, or of any machinery space in which oil fuel units or settling tanks are situated. The quantity of froth which can be discharged shall be ample to cover to a depth of 15-24 centimetres (6 inches) the whole area of the plating formed in any one compartment by the inner bottom plating, or by the shell plating of the vessel, if there is no double-bottom tank. If the engine and boiler rooms are not entirely separate, and fuel can drain from the boiler room bilges into the engine room, the combined engine and boiler rooms shall be considered as one compartment. The apparatus shall be operated and controlled from outside the com- partment in which the fire may occur. (e.) In addition to the foregoing, one extinguisher of the froth type of at least 136 litres (30 gallons) capacity in steamships having one boiler room and two such extinguishers in steamships with more than one boiler room. These extinguishers shall be provided with hoses on reels suitable for reaching any part of the boiler rooms and spaces containing oil-fuel pumping units. Equally efficient apparatus may be accepted in place of the 136 litres (30-gallons) extinguishers. (f.) All containers and valves by which they are operated shall be easily accessible and so placed that they will not readily be cut off from use by an outbreak of fire. 8. In vessels propelled by internal combustion engines there shall be provided in each of the machinery spaces, in addition to means whereby two powerful jets of water may be rapidly and simultaneously directed into any part of the machinery spaces, together with suitable spraying conductors, froth extinguishers as follows:- (a.) At least one approved 45 litres (10-gallons) extinguisher with an addition of one approved 9 litres (2-gallons) extinguisher for each 1,000 B.H.P. of the engines, but the total number of 9 litres (2-gallons) extinguishers so supplied shall be not less than two and need not exceed six. (b.) When a donkey boiler is situated in the machinery space there shall be provided, in place of the 45 litres (10-gallons) extinguisher mentioned above, one of 136 litres (30 gallons) capacity, fitted with suitable hose attachments or other approved methods for distributing the froth. 9. In steamships using oil fuel, if the engine and boiler rooms are not entirely separated by a steel bulkhead, and if fuel oil can drain from the boiler-room bilges into the engine room, one of the fire pumps shall be situated in the tunnel or other space outside the machinery compartment. When more than two pumps are required they shall not all be fitted in the same space. 1260