Page:NIOSH Manual of Analytical Methods - Chapter D.pdf/7

This page has been validated.

reduction in total sampling time or 28 min at 0.2 L/min might be done. This is very close to the original sampling time of 30 min. With the safety factors built in, collecting a 6-L sample should not be a problem. Alternately, the flow could be reduced to 0.1 L/min and be well within the 5-L total volume.

TWA Determination: In this same situation, the goal is to collect 8-h samples for comparison to the 100 ppm TWA. If sampling were done at 0.05 L/min, then the total sample volume would be 22.5 L, substantially above the 5-L recommended sample volume. If the flow was dropped to 0.02 L/min, then the sample volume would be 9 L. This sample volume might be acceptable if the styrene concentrations are around 100 ppm and no other competing organics are present, e.g., acetone. However, the safer approach would be to collect two consecutive samples at 0.02 L/min for 4 h (total sample volume of 4.8 L each).

b. Pushing a Method to the Limit, Limit of Quantitation
Given Parameters: Method 1009 for Vinyl Bromide (VB)
Recommended Sample Volume: <10 L @ 0.20 L/min or less
Working Range: 0.3 to 33 ppm (1.3 to 145 mg/m³) for a 6-L air sample; this equals 8 to 355 µg VB per tube
Limit of Detection: 3 Fg VB per tube

In this particular example, let us say that the object is to estimate exposure to vinyl bromide down to 0.1 ppm (0.44 mg/m³), which is below the working range. In order to collect 8 µg of vinyl bromide (the limit of quantitation) at this concentration, 20 L of air will have to be collected. This volume is substantially above the maximum recommended sample volume of 10 L. Since the recommended sample volume is generally a conservative value used to protect against breakthrough under worst case conditions (i.e., high humidity and high concentrations), considerable leeway exists for the size of the air sample. In this example, the 20-L air samples should be taken at 0.2 L/min or slower, and the possibility of breakthrough should be monitored by observing the relative amounts of analyte on the backup sections of the samples.

The best approach is to consult with the analytical laboratory and then to take a sufficient number of samples to determine the useful limits of the sampler in the particular application. The presence of high relative humidity and other organic solvents will severely reduce the number of active sites available on the sorbent for collection of the contaminant of interest. In pushing a method to the limit, it is often necessary to sample beyond the breakthrough volume, while observing recommended maximum sampling flow rate, in order to obtain the sensitivity to determine the concentration of interest. If this is done, then the risk must be accepted that the method may not work outside the limits tested.

c. Sampling for Dusts Using a Membrane Filter
Given parameters: Method 7401 for Alkaline Dusts
Recommended Sample Volume: 70 L @ 2 mg/m³; 1000 L max.
Useful Range of the Method: 0.76 to 3.9 mg/m³
1/15/98
23
NIOSH Manual of Analytical Methods