OSHA PEL 2 mg/m³ (NaOH)
Recommended Flow Rate: 1 to 4 L/min

Suppose it is desired to determine both an exposure taking place during a specific 20 minute operation as well as a TWA exposure of workers exposed to sodium hydroxide and the concentrations are unknown.

20 Minute Process Sample: This sample would meet the method conditions by sampling for the 20 minutes at 4 L/min since this would collect 80 L. Sampling at 1, 2, or 3 L/min for 20 minutes would probably not allow for the collection of sufficient sample required for analysis.

TWA Determination: In this situation, it is necessary to collect an 8-h sample to compare with the 2 mg/m³ OSHA PEL. Since an 8-h TWA sample covers 480 minutes, sampling can no longer be done at 4 L/min since this would collect 1920 L, almost twice the upper recommended sample volume. Sampling at 1 L/min would collect a 480 L sample, and sampling at 2 L/min would collect a 960 L sample, both acceptable per the conditions of the method.

3. BULK SAMPLES

The addition of bulk samples can often make the difference between a successful or unsuccessful sampling effort. This is especially true where there is mixed solvent exposure or unknown dust exposure and for determining silica content of dusts. The primary purpose of bulk samples is to provide the analytical laboratory with a large enough sample for qualitative and sometimes quantitative analysis. The two major types of bulk samples are bulk air and mass bulk (liquid or solid) samples.

a. Bulk Air Samples

Generally, a bulk air sample is defined as a large volume area sample collected for the purpose of qualitative analysis. A good example is multiple solvent exposure where the exact identity of the airborne solvents is unknown, e.g., painting operations. For most organic solvents, a bulk air sample consists of a charcoal tube (or whatever sorbent is called for) collected at 1 L/min for an hour or more. Although the sample is likely to exhibit breakthrough, this does not matter since one is primarily interested in what substances are present rather than their exact concentrations (the latter aim is accomplished through the separate collection of proper samples). Any questions concerning how or whether or not a bulk air sample is needed should be addressed to the analytical laboratory prior to sampling. In the case of silica, either a bulk air or solid bulk sample (e.g., a rafter sample) or both are suggested so that enough material will be available to determine free silica content.

b. Bulk Liquids and Solids

Collection of bulk materials may be needed to establish the substances present in the workplace and, in some cases, to establish the relative levels of certain substances present in the raw material. A good example of the latter is the case of mixed solvent exposure when determining if a certain contaminant of interest is present, e.g., benzene. In some cases, a list of 30 solvents may be present (from Material Safety Data Sheets), but it is not certain

1/15/98
24
NIOSH Manual of Analytical Methods