This page has been validated.
radio-active substances.
57

should be immaterial if the passage through the screens does not transform the rays; if, on the contrary, each screen transforms the rays during transmission, the order of the screens is of moment. If, for example, the rays are transformed into more absorbable rays in passing through lead, and no such effect is produced by aluminium, then the system lead-aluminium will be more opaque than the system aluminium-lead; this takes place with Röntgen rays.

My experiments show that this phenomenon is produced with the rays of polonium. The apparatus employed was. that of Fig. 8. The polonium was placed in the box, c c c c, and the absorbing screens, of necessity very thin, were placed upon the metallic sheet t.

Screens employed. Thickness.
M.m.
Current observed.
Aluminium ......... 0·01  17·9
Brass ............ 0·005
Brass ............ 0·005   6·7
Aluminium ......... 0·01
Aluminium ......... 0·01 150
Tin ............... 0·005
Tin ............... 0·005 125
Aluminium ......... 0·01
Tin ............... 0·005  13·9
Brass ............ 0·005
Brass ............ 0·005   4·4
Tin ............... 0·005

The results obtained prove that the radiation is modified in passing through a solid screen. This conclusion accords with the experiments in which, of two similar superposed metallic screens, the first is less absorbent than the second. From this it is probable that the transforming action of a screen increases with the distance of the screen from the source. This fact has not been verified, and the nature of the transformation has not been studied in detail.

I repeated the same experiments with a very active salt of radium; the result was negative. I only observed insignificant variations in the intensity of the radiation transmitted with interchange of the order of the screens. The following systems of screens were experimented with:—